{"messages":[{"status":"ok","category":null}], "collection":[{"title":"Feasibility of AI-Guided Handheld Echocardiography for Rheumatic Heart Disease Screening by Non-Cardiologists in Rural Nepal: A Mixed-Methods Diagnostic Accuracy Study","authors":"Alattar, H.; Magesh, D.; Pal, A.; Mureau-Haines, R.; Young, T.; Ronen, K.; Zhang, D.; Pal, J.","author_corresponding":"Jay Pal","author_corresponding_institution":"University of Washington","doi":"10.64898\/2026.11.12.26367974","date":"2026-11-15","version":"1","type":"PUBLISHAHEADOFPRINT","license":"cc_by_nc_nd","category":"cardiovascular medicine","jatsxml":"https:\/\/www.medrxiv.org\/content\/early\/2026\/11\/15\/2026.11.12.26367974.source.xml","abstract":"Background: Rheumatic heart disease remains a major cause of preventable morbidity and mortality in rural Nepal, where access to cardiovascular specialists and echocardiography is limited. We evaluated the diagnostic accuracy and feasibility of AI-guided echocardiography performed by nurse practitioners for community-based RHD screening. Methods: We conducted a triangulation mixed-methods study (QUAN > qual) combining a paired cross-sectional diagnostic accuracy study with semi-structured interviews during community screening camps in Damak, Nepal, in November 2025. Nurse practitioners performed AI-guided handheld echocardiography using EchoNous Kosmos Plus devices, with cardiologist overread serving as the comparator. Diagnostic performance was assessed using sensitivity, specificity, and kappa. Interviews were analyzed thematically. Results: Of 90 participants enrolled, 76 were included in the final analysis. Mean age was 50.8 years, 57.8% were male, and 42.2% had undergone prior cardiac evaluation. Detection of any valvular lesion demonstrated 95.8% sensitivity and 100% specificity, with near-perfect agreement with cardiologist interpretation (?=0.97). Lesion-specific performance included mitral regurgitation sensitivity 66.7% and specificity 97.3% (?=0.55), mitral stenosis sensitivity 100% and specificity 97.2% (?=0.81), aortic regurgitation sensitivity 90.9% and specificity 96.9% (?=0.84), and tricuspid regurgitation sensitivity and specificity of 100% (?=1.00). Mean scan duration was 5.8 minutes. Portability, AI-assisted acquisition, and remote review facilitated implementation, while training needs, workflow constraints, and technical issues were barriers. Conclusions: AI-guided handheld echocardiography performed by nurses demonstrated high diagnostic accuracy and feasibility for rural RHD screening. AI-assisted task-shifting may expand access to early RHD detection in underserved settings.","funder":"NA","published":"NA","server":"medRxiv"}]}



